Data Centre Liquid Cooling (Air & Liquid series)CDU

PRODUCT DETAIL

Coolant Preparation & Delivery

Air&Liquid CDU
·Suitable for computer room upgrades, laboratories, and other scenarios. Features fiexible deployment and convenient operation & maintenance.
Manifold
·Key Role. Balances fiow to prevent local overheating, supports hot-swapping to reduce operation and maintenance costs.
·System Value: Adapts to liquid cooling requirements of various power ratings and architectures, helps optimize cabinet PUE, and improves heat dissipation reliability.

Liquid-Cooled Door
·Cabinet-Level Air-liauid Conversion: Uparade the liauid-cooled door to the main heat exchanger of the Air-liguid Cou, directhutilizing the cold air in the computer room for coolant circulation, achieving full heat capture of 30kW per cabinet.
·Passive Air-Liauid Heat Exchange: As the heat exchanae terminal of the CDU, it passivly uses the air flow in the computer room forcooling, enabling near-zero eneray consumption free cooling, sianificantly reducing PUE and noise.
·Integrated Thermal Management: As theexchanger of the CDU.it achieveszero heat leakage in the cabinet, supportsmixed deployment of air-cooled and iquid-cooled servers, and is compatible with GPU server upgrades in existing computer rooms.
Water Pump
·Works with water manifolds to regulate flow, ensuring uniform heat dissipation forend equipment.

Water Tank
·Absorbs flow fluctuations caused by simultaneous water demand from multiple cabinets, ensuring stable coolant supplyto each cabinet.
Dry Cooler
·Requires no water consumption, suitable for water-scarce areas, and avoids watelconsumption and scale issues assocated with traditional coolina towers.
·Stabilizes the temperature of the primary-side coolant, supplving low-temperatureliquid for subsequent cycles to ensure system heat dissipation efficiency.

Refrigeration Module
·Eneray Saving & Consumption Reduction: The liguid cooling system reduces significant power consumption required foair cooling, delivering higher cooling efficiency compared to traditional cooling methods.
·High -Density Deployment: As high-density Al applications expand, traditional air cooling solutions fail to meet heat dissipation demands, High-efficiency chillers support efficient heat exchange.
Product Parameter
| Parameter Category | Parameter Item | Specifications |
| I. Core Performance | Rated Cooling Capacity | 30kW |
| Max Operating Power | ≤550W (Full load) | |
| Heat Dissipation Mode | Air-liquid dual-mode, switchable to pure air cooling | |
| Max Load per Rack |
13kW (Liquid cooling branch) |
|
| Temp Control Accuracy | ±1°C (Inside rack) | |
| II. Fluid & Air System | Fan Air Volume (Air branch) | 800m³/h, stepless speed regulation |
| Temp Difference (Liquid branch) | 5℃ (Primary/secondary side, rated load) | |
| Air-Liquid Ratio Control | Intelligent dynamic regulation (By workload/temperature) | |
| Secondary Side Water Supply | 60LPM, 0.8Bar residual pressure | |
| Applicable Coolant | Ethylene glycol/propylene glycol solution (Primary/secondary side) | |
| Water Pump Config | 1+1 redundancy, auto seamless switch, low noise | |
| Typical Primary Side Pressure Drop | 0.6Bar (50LPM, 20% ethylene glycol) | |
| III. Piping & Filtration | Piping Interface | 1-inch sanitary clamp (Primary/secondary side), optional quick-connect |
| Secondary Side Filter | Built-in 50μm cleanable filter, low pressure loss | |
| Liquid Holding Capacity | 4L (Primary), 8L (Secondary) | |
| IV. Electrical | Input Power | Single-phase AC 85~265V, 50/60Hz |
| Power Supply Redundancy | Dual power, 1+1 redundancy | |
| Fan Protection | Overcurrent/overheat protection, auto shutdown + alarm | |
| V. Physical & Env | Rack Size | 6U standard, 19-inch compatible, depth ≤800mm |
| Dry Weight | ≤50kg | |
| Operating Noise (3m) | <55dBA (Full load) | |
| Operating Env Temp/Humidity | 5℃~45℃ / 10%~90%RH (Non-condensing) | |
| Protection Grade | IP54 | |
| VI. Monitoring & Communication | Multi-Monitoring | Temp/flow/pressure/fan/pump status (Full-dimension real-time) |
| Alarm Function | Local acousto-optic + remote signal (Over-temp/over-pressure/flow break, etc.) | |
| Communication Protocols | RS485 RTU Modbus, TCP/IP SNMP (DCIM/BMS compatible) | |
| HMI | Local HD touch screen (Parameter setting/ status/ historical data) | |
| VII. Auxiliary Components | Water Make-up & Air Vent |
Auto pump-type make-up + manual vent |
| Expansion Tank | 0.8L, stabilizes liquid circuit pressure | |
The above data is for reference only; specific data is subject to the product nameplate. |
||