Data Centre Liquid Cooling (Liquid & Liquid series)CDU

Liquid-to-Liquid CDU of HEEALARX Data centre liquid cooling system: A rack-level liquid cooling solution for high-densitycomputing,Seamlessly fits standard 19-inch server racks, enabling fast large-scale deplovment of hioh-power iguid-cooledservers with no major retrofits to existing data center cooling systems.

    6

    PRODUCT DETAIL

    The cooling capacity distribution controller is a CDU liquid cooling control unit that can be installed in a 19-inch standard server cabinet. Through liquid-liquid exchange, the system can provide a safe, reliable, and clean liquid cooling circulation system control for liquid-cooled server.

    液&液CDU11

    Deployment &Connection

    Designed as a 6Urack-mount unit, the CDU installs side-by-side withservers.lt connects to the supply/return liquidports of CPU/GPU cold plates via quick-connectfittings and short-distance pipelines.


    液&液CDU1

    Liquid &Liquid CDU

    ·Rack Integration: Designed for direct installation within server racks to achieve compact, close-proximity cooling.
    ·Localized Heat Dissipation: Efficiently manages coolant distribution and heat exchange for single or a few cabinets, targeting local hotspots.
    ·Flexible Expansion: Modular design allows flexible deployment and scaling to meet demand, suitable for high thermaldensity areas.

    Manifold 

    ·Connects CDUs to server cold plates, distributes low-temperature coolant, and collectshiah-temperature coolant.
    ·Balances flow to prevent local overheating and supports hot-swapping to reduce maintenance costs.
    ·Adapts to liquid cooling needs of multiple power architectures, helping optimize cabinet PUE and improving heat dissipation reliabilit.

    Manifold
    Liquid-CooledRear Door

    Liquid-Cooled Rear Door

    ·Active Heat Dissipation: Equipped with fans or pumps, forcing airflow through the heat exchanger to more efficienthremove server heat.
    ·High-Density Eficiency: Handles ultra-high-density cabinets, delivering exceptional cooling performance while maintain.ing stable data center temperature.
    ·Precise Control: Adiusts fan or pump speed based on load for finer cooling management and energy savings.

    Water Pump

    ·Drives power for the entire full liquid cooling system, circulating the coolant.
    ·Works with water manifolds to regulate flow, ensuring uniform heat dissipation forend equipment.
    ·Collaborates with the water tank to supplement pressure and vent air, maintainingsystem stability.

    Water Pump
    Water Tank

    Water Tank

    ·Stores sufficient coolant to balance liquid volume across multiple rear doors.
    ·Absorbs flow fluctuations caused by simultaneous water demand from multiple cabinets, ensuring stable coolant supplyto each cabinet.
    ·Balances system pressure to prevent sudden pressure drops caused by insufficient chiler supply.

    Dry Cooler

    ·Cools the hot water discharged from servers through air convection, dissipatingheat to the outdoors to complete heat exchange.
    ·Requires no water consumption, suitable for water-scarce areas, and avoids watelconsumption and scale issues assocated with traditional coolina towers.
    ·Stabilizes the temperature of the primary-side coolant, supplving low-temperatureliquid for subsequent cycles to ensure system heat dissipation efficiency.

    Dry Cooler
    Refrigeration Module

    Refrigeration Module

    ·Precise Temperature Control: liguid cooling chillers precisely control water temperature and fow to ensure equipmenttemperature remains within the optimal range at all times.
    ·Eneray Saving & Consumption Reduction: The liguid cooling system reduces significant power consumption required foair cooling, delivering higher cooling efficiency compared to traditional cooling methods.
    ·High -Density Deployment: As high-density Al applications expand, traditional air cooling solutions fail to meet heat dissipation demands, High-efficiency chillers support efficient heat exchange.

    Product Parameter

    Parameter Category Parameter Item Specifications
    I. Core Performance Rated Cooling Capacity 50kW
    Heat Exchange Temp Difference 4℃ @50kW cooling
    Max Operating Power ≤700W
    II. Fluid Circuit Secondary Water Supply 100LPM, 1Bar
    Secondary Coolant Ethylene glycol / PG25
    Pump Redundancy 1+1, auto seamless switch
    Primary Pressure Drop 0.8Bar (80LPM, 20% glycol)
    Secondary Temp Control 10~45℃, dew point control
    III. Piping & Filtration Primary Pipe Interface 1-1/2" sanitary clamp
    Primary Volume 6L
    Secondary Pipe Interface 1-1/2" sanitary clamp, optional quick connect
    Secondary Filter 50μm cleanable filter
    Secondary Volume 10L
    IV. Electrical Input Power Single-phase AC 85~265V, 50/60Hz
    Power Redundancy Dual power redundancy
    V. Physical & Env Dimensions & Weight 175×445×900mm, 65kg
    Operating Noise 58dBA @3m
    VI. Monitoring System Flow Monitoring Primary & secondary full flow
    Pressure Monitoring Supply/return/filter/system differential
    Temperature Monitoring Primary inlet, secondary supply/return
    Env Monitoring Room temp & humidity real-time
    Communication RS485 Modbus, TCP/IP SNMP, DCIM compatible
    VII. Auxiliary Components Water Make-up & Vent Auto pump make-up + manual vent
    Expansion Tank 1L for pressure stabilization

    The above data is for reference only; specific data is subject to the product nameplate.